Effect of Electro Hydrodynamic Effect on Modified Condenser with Performance Evaluation Refrigeration System
Keywords:
Condensation heat switch, COP, electrical area strengths, electrodes, Electro hydrodynamicAbstract
Outcomes of carried out of EHD at the performance of vapour compression refrigeration
device are experimentally investigated to present applicability of the EHD method. inside the
experimental work the condenser section is changed simplest. The refrigerant is cooled by
way of dielectric fluid (transformer oil). Checks had been executed at 21-22 LPH of
refrigerant drift and at different electric subject strengths (0-250 V), while average
saturation temp was 54°C and 6°C. Experimental results exhibit a brilliant capability in
utilising EHD to decorate condensation warmness switch. it's far concluded that the
enhancement is pushed through the effective removal of the condensate thru EHD caused
liquid extraction and dispersion phenomena. For the presence of the electrodes, the
experimental effects suggest that the most heat transfer charge received is 1.092040 kJ/sec
and COP actual received is 4.908 that's 3 to 4instances extra than without the EHD impact.
This approach can be utilised correctly to the refrigeration device to have higher COP and
additionally size of condenser as well as evaporator can be various.